Commercial compliance directory

United States · No. 01

Facility InspectRequest quotesQuotes

Vertical 02 · Live

Fire sprinkler and alarm inspection.

Water-based systems and fire alarms are not on one shared calendar. These city pages list companies from their own websites, and the intervals owners ask about most often.

Which standard is which

NFPA 25 is inspection, testing, and maintenance of water-based systems: sprinklers, standpipes, private mains, fire pumps, and tanks. It is not the design standard. Installation is NFPA 13.

NFPA 72 is fire alarm and signaling systems, including inspection and testing. Device tests are commonly annual. Control-equipment inspection is more frequent when the panel is not monitored.

The local fire marshal adopts the edition and decides who is qualified. Taking a system out of service is an impairment, with its own notification rules. This directory does not walk through that procedure. Standards are published by NFPA.

Common intervals. Not the full ITM table.
OperationInterval
Sealed control valvesInspection. Locked or electrically supervised valves are on a monthly inspection instead.NFPA 25Weekly
GaugesInspection on wet systems. Replacement or calibration is a separate multi-year item.NFPA 25Monthly
Waterflow alarmsTest of the alarm device. Supervisory devices have their own row in the ITM table.NFPA 25Quarterly
Sprinklers, pipe, and hangersInspection. A main drain test is annual, and quarterly where the supply passes through a backflow or pressure-reducing valve.NFPA 25Annually
Fire pumpNo-flow (churn) test: weekly for diesel, monthly for electric. A full flow test is annual.NFPA 25Weekly / monthly
Alarm devicesSmoke detectors, heat detectors, manual stations, and notification appliances. Control-unit inspection is more frequent when the panel is not monitored.NFPA 72Annually

Cities in this edition

Verified Provider Directory — 53 listings

Names, websites, phones, and service areas below are copied from each company’s own site. IKECA is shown only when that site lists the certification. These are not ratings.

16 cities.

Washington

Arizona

California

Colorado

Florida

Georgia

Illinois

New York

Texas

Request quotes

The form is a request for sprinkler inspection, alarm inspection, or both. It does not publish a listing and it does not assign a contractor.

List your company

No account

Request free compliance quotes

Sprinklers, alarms, or both. Say the city and how to reach you.