Commercial compliance directory

United States · No. 01

Facility InspectRequest quotesQuotes

Tank testing · WA

Seattle

Underground storage tank testing in Seattle, Washington.

Verified Provider Directory — 4 listings in Seattle

  • FuelCare

    Washington Ecology certified UST service provider (TPT, CP)

    fuelcareusa.com

    (206) 286-6500

    Tightness testing · Compliance inspection · Cathodic protection

    Washington, including Seattle and the Puget Sound

    Source: Company website

  • Mascott Equipment Co.

    Washington Ecology certified UST service provider (TPT, CP)

    mascottec.com

    (206) 763-7867

    Tightness testing · Compliance inspection

    Seattle and Western Washington

    Source: Company website

  • Left Coast Services

    Washington Ecology certified UST service provider (TPT, CP)

    leftcoast.services

    (206) 762-7500

    Tightness testing · Cathodic protection

    Washington and Oregon, including Seattle

    Source: Company website

  • Tanknology

    Washington Ecology certified UST service provider (TPT, CP)

    tanknology.com

    (800) 964-0180

    Tightness testing · Compliance inspection · Cathodic protection

    Washington, including Seattle and the Puget Sound

    Source: Company website

Names, websites, phones, and service areas are copied from each company’s own site. IKECA is shown only when that site lists the certification. Facility Inspect does not grade companies and does not show star ratings.

Authority having jurisdictionSeattle Fire Department

Seattle’s commercial kitchens run from downtown service to neighborhood rooms with solid-fuel and wok lines. The inspection tier follows the cooking, not the neighborhood. Confirm the adopted fire code, and any rule for keeping the cleaning record on site, with the Seattle Fire Department.

No account

Request free compliance quotes

Quotes for Seattle. Change the city if the site is next door.

Email or phone is required. A quote also needs the business name, type, and timeline. The form posts to /api/quote. A contractor is contacted only after delivery is configured for this deployment. Nothing here is a booked service.Privacy

Federal UST baselines

These are the federal baselines in 40 CFR 280.35 and 280.36. A state program can be stricter, and double-walled equipment that is monitored on the walkthrough cycle can follow that option instead of the three-year test. Confirm the rule with the state UST program before you hire.

40 CFR 280 walkthroughs and tests
OperationInterval
Walkthrough, spill prevention and release detectionVisual check of spill equipment, and a check that release detection is operating without alarms. Spill equipment at sites with infrequent deliveries may be checked before each delivery instead.40 CFR 280.36Every 30 days
Walkthrough, sumps and handheld devicesContainment sumps, and handheld release-detection devices such as gauge sticks or bailers.40 CFR 280.36Annually
Spill buckets and piping sumpsLiquid-tight test of spill prevention equipment and of containment sumps used for interstitial monitoring of piping, unless both walls of double-walled equipment are monitored on the walkthrough cycle.40 CFR 280.35Every 3 years
Overfill preventionInspection that overfill equipment is set to activate at the required level and will activate when product reaches it.40 CFR 280.35Every 3 years

Federal rule and EPA source

List a company in Seattle

A basic listing is free and is not published from the form alone. Featured placement is a request, with no rate card in this edition.

List your business